Engine
Engine Specifications 1.800 r.p.m.
Rated Engine Output: 522kW prp ; 577kW standby
Manufacturer: YANMAR
Model: 6F141TE1W.GL
Engine Type: 4-stroke diesel
Injection Type: Direct
Aspiration Type: Turbocharged and after-cooled
Number of cylinders and arrangement: 6-L
Bore and Stroke: 141 x 170 mm
Displacement: 15,9 L
Cooling System: Liquid (water + 50% glycol)
Lube Oil Specifications: ACEA E3 - E5
Compression Ratio: 16,5:1
Fuel Consumption ESP: 139,07 l/h
Fuel Consumption 100% PRP: 124,88 l/h
Fuel Consumption 80 % PRP: 100,12 l/h
Fuel Consumption 50 % PRP: 64,42 l/h
Lube oil consumption with full load: 0,2 % of fuel consumption
Total oil capacity including tubes, filters 38 L
Total coolant capacity: 66,5 L
Governor Type Electrical
Air Filter Type Dry
Diesel engine
4-stroke cycle
Water-cooled
24V electrical system
Water separator filter (no visible level)
Dry air filter
Radiator with pusher fan
Radiator water level sensor
HTW sender
LOP sender
Hot parts protection
Moving parts protection
Alternator
Generator: STAMFORD
Model: HCI544D
Poles: 4
Connection type (standard): Star-series
Mounting type: S-1 14"
Insulation: H class
Enclosure (according IEC-34-5): IP23
Exciter system: Self-excited, brushless
Voltage regulator: A.V.R. (Electronic)
Bracket type: Single bearing
Coupling system: Flexible disc
Coating type: Standard (Vacuum impregnation)
Version
- OPEN SET VERSION.
Steel chassis
Emergency stop button
Oil sump extraction kit
Anti-vibration shock absorbers
Chassis with integrated fuel tank
Fuel level gauge
Fuel tank drain plug
Steel industrial silencer -15db(A) attenuation
Fuel transfer pump (Optional)
Steel residential silencer -35db(A) attenuation. (Optional)
Installation
- ELECTRICAL SYSTEM.
Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
Battery Switch
Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
Battery charger (standard on gensets with automatic control panels)
Heating resistor (standard on sets with automatic control panels)
Battery charger alternator with ground connection
Starter battery/ies installed (cables and bracket included)
Ground connection electrical installation with connection ready for ground spike (not supplied)
- EXHAUST SYSTEM.
Maximum exhaust temperature: 554 ºC
Maximum allowed back pressure: 7 kPa
- NECESSARY AMOUNT OF AIR.
Intake air flow: 2995 m3/h
Cooling Air Flow: 13,05 m3/s
Alternator fan air flow: 1,312 m3/s
- STARTING SYSTEM.
Starting power: 5,5 kW
Starting power: 7,48 CV
Auxiliary Voltage: 24 Vdc
- FUEL SYSTEM
Fuel Oil Specifications: Diesel
Fuel Tank: 740 L
Dimensions
- DIMENSIONS.
Length: 3.600 mm
Width: 1.460 mm
Weight with liquids in radiator and sump: 3.445 kg
Fuel tank capacity: 740 L
Autonomy: 7 Hours