HRGP-110 T5 LPG

Mobile Power / HR RANGE

HRGP-110 T5 LPG

Rental

Prime power109 kVA
Standby power121 kVA

TECHNICAL DATA

Specifications

Model code
G-1298-1-1-1
Engine
PSI
Alternator
STAMFORD
Fuel
LPG
Frequency
50 Hz
Phase
Three phase
Emissions
non certified
Version
Rental
Prime power
87 kW
Standby power
97 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase STAMFORD —

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 96,2kW prp ; 107,7kW standby Manufacturer: PSI Model: 8.8L NA Engine Type: 4-stroke Otto Cycle Injection Type: Carburization Aspiration Type: Natural Number of cylinders and arrangement: 8-V Bore and Stroke: 110,5 x 114,3 mm Displacement: 8,8 L Cooling System: Coolant Lube Oil Specifications: API ≥SM, SAE 5W30 Compression Ratio: 10,1:1 Total oil capacity including tubes, filters 7,6 L Governor Type Electrical Air Filter Type Dry LPG-liquefied petrol gas engine 4-stroke cycle Water-cooled 12V electrical system Dry air filter Radiator with pusher fan Electronic governor Hot parts protection Moving parts protection HTW sender (Optional) LOP sender (Optional)

Alternator

Generator: STAMFORD Model: UCI274D Poles: 4 Connection type (standard): Star-series Mounting type: S-3 11"1/2 Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- SOUNDPROOFED VERSION. Steel chassis Anti-vibration shock absorbers External emergency stop switch Bodywork made from high quality steel plate High mechanical strength Low noise emissions level Soundproofing provided by high-density volcanic rock wool Epoxy polyester powder coating Full access for maintenance (water, oil and filters, no need to remove the canopy) Reinforced lifting hooks for crane hoisting Chassis drain plug Steel residential silencer -35db(A) attenuation. Oil sump extraction kit IP Protection according to ISO 8528-13:2016 - GAS RAMP. Manual shut-off valve Gas filter Double solenoid valve Primary pressure regulator Secondary pressure regulator (Zero pressure regulator) Low pressure switch Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence High pressure regulator (Optional) High pressure switch (Optional)

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Battery Switch (Optional) - EXHAUST SYSTEM. Maximum exhaust temperature: 705 ºC Exhaust Gas Flow: 18,76 m3/min Maximum allowed back pressure: 10,2 kPa Exhaust Flange Size (external diameter): 90 mm - NECESSARY AMOUNT OF AIR. Intake air flow: 348,6 m3/h Alternator fan air flow: 0,514 m3/s - STARTING SYSTEM. Starting power: 1,7 kW Starting power: 2,31 CV Recommended battery: 115 Ah Auxiliary Voltage: 12 Vdc - FUEL SYSTEM Fuel Oil Specifications: LPG

Dimensions

- DIMENSIONS. Length: 2.810 mm Height: 2.360 mm Width: 1.150 mm Maximum shipping volume: 7,63 m3 Weight with liquids in radiator and sump: 2.608 kg Sound pressure level: 71 ± 2,4 dB(A)@7m