HGS-305 T5 LPG

On-Site Power / HI RANGE

HGS-305 T5 LPG

Open Skid

COP power303 kVA

TECHNICAL DATA

Specifications

Model code
G-1859-7-1-3
Engine
GUASCOR
Alternator
STAMFORD
Fuel
LPG
Frequency
50 Hz
Phase
Three phase
Emissions
non certified
Version
Open Skid

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase STAMFORD
415/240 V 50 Hz Three phase STAMFORD
380/220 V 50 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 315kW cop Manufacturer: GUASCOR Model: G.18SM Engine Type: 4-stroke Otto Cycle Injection Type: Carburization Aspiration Type: Turbocharged Number of cylinders and arrangement: 6-L Bore and Stroke: 152 x 165 mm Displacement: 18 L Cooling System: Water + Antifreeze Lube Oil Specifications: SAE 40 Compression Ratio: 9,2 Fuel Consumption 100% PRP: 791 kW Fuel Consumption 80 % PRP: 655 kW Fuel Consumption 75 % PRP: 615 kW Fuel Consumption 50 % PRP: 443,2 kW Fuel Consumption 25 % PRP: 285,1 kW Lube oil consumption with full load: 0,35 Total oil capacity: 86 L Governor Type Electrical Air Filter Type Semi-humid LPG-liquefied petrol gas engine 4-stroke cycle Water-cooled Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: S5L1S.C4 Poles: 4 Connection type (standard): Star-series Mounting type: S-0 18'' Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Double drive-shaft Coupling system: Elastic Coupling Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Emergency stop button Steel chassis Anti-vibration shock absorbers Steel industrial silencer -15db(A) attenuation Steel residential silencer -35db(A) attenuation. - GAS RAMP. Manual shut-off valve Gas filter Double solenoid valve High pressure regulator Primary pressure regulator Low pressure switch High pressure switch Valve (tightness) testing system Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence

Installation

- ELECTRICAL SYSTEM. Maintenance-free and anti-explosion battery Battery charger Water Jacket Heater Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) - EXHAUST SYSTEM. Maximum exhaust temperature: 450 ºC Exhaust Gas Flow: 0,39 kg/s Maximum allowed back pressure: 450 mm H2o - NECESSARY AMOUNT OF AIR. Alternator fan air flow: 1,12 m3/s - STARTING SYSTEM. Auxiliary Voltage: 12 Vdc - FUEL SYSTEM Fuel Oil Specifications: LPG