HGP-720 T5 NG

On-Site Power / HI RANGE

HGP-720 T5 NG

Open Skid

Prime power716 kVA
Standby power844 kVA

TECHNICAL DATA

Specifications

Model code
G-1888-10-3-3
Engine
PSI
Alternator
STAMFORD
Fuel
Natural Gas
Frequency
50 Hz
Phase
Three phase
Emissions
non certified
Version
Open Skid
Prime power
573 kW
Standby power
675 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase STAMFORD
415/240 V 50 Hz Three phase STAMFORD
380/220 V 50 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 643kW prp ; 717kW standby Manufacturer: PSI Model: 40L Engine Type: 4-stroke Otto Cycle Injection Type: Direct Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 12-V Bore and Stroke: 150 x 185 mm Displacement: 39,2 L Cooling System: Coolant Lube Oil Specifications: SAE 15W40; API CD or CE Compression Ratio: 10,5:1 Fuel Consumption ESP: 2088 kW Fuel Consumption 100% PRP: 1829 kW Fuel Consumption 75 % PRP: 1430 kW Fuel Consumption 50 % PRP: 1030 kW Fuel Consumption 25 % PRP: 632 kW Total oil capacity: 146 L Total coolant capacity: 172 L Governor Type Electrical Air Filter Type Dry Natural Gas engine 4-stroke cycle Water-cooled Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: S6L1D.C4 Poles: 4 Connection type (standard): Star-series Mounting type: S-0 18'' Insulation: H class Enclosure (according IEC-34-5): IP23 Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Emergency stop button Steel chassis Anti-vibration shock absorbers Steel industrial silencer -15db(A) attenuation Steel residential silencer -35db(A) attenuation. - GAS RAMP. Manual shut-off valve Gas filter Double solenoid valve High pressure regulator Primary pressure regulator Low pressure switch High pressure switch Valve (tightness) testing system Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Battery Switch Adjustable earth leakage protection (time & sensitivity) standard in M12, with thermal magnetic protection Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) - EXHAUST SYSTEM. Maximum exhaust temperature: 639 ºC Exhaust Gas Flow: 104 m3/min Maximum allowed back pressure: 13 kPa - NECESSARY AMOUNT OF AIR. - STARTING SYSTEM. Starting power: 10 kW Starting power: 13,6 CV Recommended battery: 75 x 4 Ah Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: Natural Gas

Dimensions

- DIMENSIONS. Length: 4.500 mm Height: 2.400 mm Width: 2.200 mm Maximum shipping volume: 23,76 m3