HGP-420 T6 LPG

On-Site Power / HI RANGE

HGP-420 T6 LPG

Open Skid

Prime power425 kVA
Standby power508 kVA

TECHNICAL DATA

Specifications

Model code
G-1292-11-6-3
Engine
PSI
Alternator
MECC ALTE
Fuel
LPG
Frequency
60 Hz
Phase
Three phase
Emissions
Cumple EPA
Version
Open Skid
Prime power
340 kW
Standby power
407 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
380/220 V 60 Hz Three phase MECC ALTE
416/240 V 60 Hz Three phase MECC ALTE
480/277 V 60 Hz Three phase MECC ALTE
208/120 V 60 Hz Three phase MECC ALTE
220/127 V 60 Hz Three phase MECC ALTE
440/254 V 60 Hz Three phase MECC ALTE
460/265 V 60 Hz Three phase MECC ALTE

INCLUDED

Equipment

Engine

Engine Specifications 1.800 r.p.m. Rated Engine Output: 356,8kW prp ; 428kW standby Manufacturer: PSI Model: 31.8L Engine Type: 4-stroke Otto Cycle Injection Type: Carburization Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 12-V Bore and Stroke: 150 x 150 mm Displacement: 31,8 L Cooling System: Liquid (water + 50% glycol) Lube Oil Specifications: API SG/SH, SAE 10W30 Compression Ratio: 10,5:1 Fuel Consumption ESP: 1436 kW Fuel Consumption 100% PRP: 1436 kW Fuel Consumption 75 % PRP: 1096 kW Fuel Consumption 50 % PRP: 805 kW Fuel Consumption 25 % PRP: 578 kW Total oil capacity: 122 L Total coolant capacity: 176,2 L Governor Type Electrical Air Filter Type Dry LPG-liquefied petrol gas engine 4-stroke cycle Water-cooled 24V electrical system Dry air filter Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: MECC ALTE Model: ECO40.1S4C Poles: 4 Connection type (standard): Star-series Mounting type: S-1 14" Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Emergency stop button Steel chassis Anti-vibration shock absorbers Steel industrial silencer -15db(A) attenuation Steel residential silencer -35db(A) attenuation. (Optional) - GAS RAMP. Manual shut-off valve Gas filter Double solenoid valve High pressure regulator Primary pressure regulator Low pressure switch High pressure switch Valve (tightness) testing system Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Battery Switch (Optional) - EXHAUST SYSTEM. Maximum exhaust temperature: 653 ºC Exhaust Gas Flow: 97 m3/min Maximum allowed back pressure: 10,2 kPa - NECESSARY AMOUNT OF AIR. Intake air flow: 1680 m3/h Cooling Air Flow: 30,72 m3/s Alternator fan air flow: 1,08 m3/s - STARTING SYSTEM. Starting power: 11,7 kW Starting power: 15,91 CV Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: LPG

Dimensions

- DIMENSIONS. Length: 4.460 mm Height: 2.670 mm Width: 2.100 mm Maximum shipping volume: 25,01 m3 Weight with liquids in radiator and sump: 6.513 kg