HGO-30 M6 NG

On-Site Power / HI RANGE

HGO-30 M6 NG

Open Skid

Prime power32 kVA
Standby power37 kVA

TECHNICAL DATA

Specifications

Model code
G-1928-8-3-3
Engine
FORD
Alternator
STAMFORD
Fuel
Natural Gas
Frequency
60 Hz
Phase
Single phase
Emissions
non certified
Version
Open Skid
Prime power
32 kW
Standby power
37 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
240/120 V 60 Hz Single phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.800 r.p.m. Rated Engine Output: 37,22kW prp ; 42,81kW standby Manufacturer: FORD Model: LSG635 Engine Type: 4-stroke Miller Cycle Injection Type: Carburization Aspiration Type: Natural Number of cylinders and arrangement: 6-V Bore and Stroke: 92,5 x 86,7 mm Displacement: 3,5 L Cooling System: Liquid (water + 50% glycol) Lube Oil Specifications: API ≥SH, SAE 10W-30 Compression Ratio: 11,8 Fuel Consumption 100% PRP: 447.73 cfh Total oil capacity including tubes, filters 5,68 L Governor Type Electrical Air Filter Type Dry Natural Gas engine 4-stroke cycle Water-cooled 12V electrical system Dry air filter Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: S1L2.R1 Poles: 4 Connection type (standard): Double delta Mounting type: S-3 11"1/2 Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Steel chassis Emergency stop button Anti-vibration shock absorbers Steel industrial silencer -15db(A) attenuation Steel residential silencer -35db(A) attenuation. (Optional) - GAS RAMP. Gas filter Double solenoid valve High pressure regulator Primary pressure regulator Low pressure switch Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence High pressure switch (Optional)

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Battery Switch (Optional) - EXHAUST SYSTEM. Exhaust Gas Flow: 6,7 m3/min Maximum allowed back pressure: 20,32 kPa - NECESSARY AMOUNT OF AIR. Intake air flow: 132 m3/h Alternator fan air flow: 0,211 m3/s - STARTING SYSTEM. - FUEL SYSTEM Fuel Oil Specifications: Natural Gas

Dimensions

- DIMENSIONS. Length: 1.950 mm Width: 900 mm