HFW-310 T5

On-Site Power / HI RANGE

HFW-310 T5

Open Skid

Prime power300 kVA
Standby power330 kVA

TECHNICAL DATA

Specifications

Model code
G-2065-7-2-3
Engine
FPT_IVECO
Alternator
MECC ALTE
Fuel
Diesel
Frequency
50 Hz
Phase
Three phase
Emissions
STAGE 3A
Version
Open Skid
Prime power
240 kW
Standby power
264 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase MECC ALTE
200/115 V 50 Hz Three phase MECC ALTE
230 V (t) 50 Hz Three phase MECC ALTE

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 262kW prp ; 292kW standby Manufacturer: FPT_IVECO Model: C87TE4F Engine Type: 4-stroke diesel Injection Type: Direct, common rail Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 6-L Bore and Stroke: 117 x 135 mm Displacement: 8,7 L Cooling System: Coolant Lube Oil Specifications: ACEA E3 - E5 Compression Ratio: 16,5:1 Fuel Consumption ESP: 74,5 l/h Fuel Consumption 100% PRP: 68,6 l/h Fuel Consumption 80 % PRP: 55,6 l/h Fuel Consumption 50 % PRP: 35,6 l/h Total oil capacity including tubes, filters 28 L Total coolant capacity: 63 L Governor Type Electrical Air Filter Type Dry Diesel engine 4-stroke cycle Water-cooled 24V electrical system Water separator filter (no visible level) Dry air filter Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: MECC ALTE Model: ECO38.1L4C Poles: 4 Connection type (standard): Star-series Mounting type: S-1 14" Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Steel chassis Emergency stop button Oil sump extraction kit Anti-vibration shock absorbers Chassis with integrated fuel tank Fuel level gauge High mechanical strength Epoxy polyester powder coating Fuel tank drain plug Steel industrial silencer -15db(A) attenuation Fuel transfer pump (Optional) Steel residential silencer -35db(A) attenuation. (Optional)

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Battery Switch Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) - EXHAUST SYSTEM. Maximum exhaust temperature: 511 ºC Exhaust Gas Flow: 0,43 kg/s Maximum allowed back pressure: 10 kPa - NECESSARY AMOUNT OF AIR. Intake air flow: 1240 m3/h Cooling Air Flow: 5,14 m3/s Alternator fan air flow: 0,533 m3/s - STARTING SYSTEM. Starting power: 4,5 kW Starting power: 6,12 CV Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: Diesel Fuel Tank: 449 L

Dimensions

- DIMENSIONS. Length: 3.000 mm Height: 1.790 mm Width: 1.160 mm Maximum shipping volume: 6,23 m3 Weight with liquids in radiator and sump: 2.542 kg Fuel tank capacity: 449 L Autonomy: 8 Hours