HBW-135 T5

On-Site Power / HI RANGE

HBW-135 T5

Open Skid

Prime power142 kVA
Standby power156 kVA

TECHNICAL DATA

Specifications

Model code
G-2149-7-3-3
Engine
BAUDOUIN
Alternator
MECC ALTE
Fuel
Diesel
Frequency
50 Hz
Phase
Three phase
Emissions
non certified
Version
Open Skid
Prime power
114 kW
Standby power
125 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase MECC ALTE
200/115 V 50 Hz Three phase MECC ALTE
230 V (t) 50 Hz Three phase MECC ALTE

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 123kW prp ; 135kW standby Manufacturer: BAUDOUIN Model: 6M11G150.5 Engine Type: 4-stroke diesel Injection Type: Direct Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 6-L Bore and Stroke: 105 x 130 mm Displacement: 6,75 L Cooling System: Liquid (water + 50% glycol) Lube Oil Specifications: API CI-4 or ACEA E7 Compression Ratio: 18 : 1 Fuel Consumption ESP: 33,1 l/h Fuel Consumption 100% PRP: 30,2 l/h Fuel Consumption 75 % PRP: 23,0 l/h Fuel Consumption 50 % PRP: 15,9 l/h Fuel Consumption 25 % PRP: 9,0 l/h Lube oil consumption with full load: 0,2 % of fuel consumption Total oil capacity including tubes, filters 19 L Total coolant capacity: 8 L Governor Type Electrical Air Filter Type Dry Inner diameter exhaust pipe: 65 mm Diesel engine 4-stroke cycle Water-cooled 12V electrical system Water separator filter (no visible level) Dry air filter Radiator with pusher fan Hot parts protection Moving parts protection Radiator water level sensor (Optional) HTW sender (Optional) LOP sender (Optional)

Alternator

Generator: MECC ALTE Model: ECP34.1L4C Poles: 4 Connection type (standard): Star-series Mounting type: S-3 11"1/2 Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Steel chassis Emergency stop button Oil sump extraction kit Anti-vibration shock absorbers Chassis with integrated fuel tank Fuel level gauge High mechanical strength Epoxy polyester powder coating Fuel tank drain plug Steel industrial silencer -15db(A) attenuation Fuel transfer pump (Optional) Steel residential silencer -35db(A) attenuation. (Optional)

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Battery Switch (Optional) - EXHAUST SYSTEM. Maximum exhaust temperature: 550 ºC Exhaust Gas Flow: 21,82 m3/min Maximum allowed back pressure: 60 mbar - NECESSARY AMOUNT OF AIR. Cooling Air Flow: 5,075 m3/s Alternator fan air flow: 0,487 m3/s - STARTING SYSTEM. Starting power: 4 kW Starting power: 5,44 CV - FUEL SYSTEM Fuel Oil Specifications: Diesel Fuel Tank: 250 L

Dimensions

- DIMENSIONS. Weight with liquids in radiator and sump: 0 kg Dry weight: 0 kg Fuel tank capacity: 250 L Autonomy: 11 Hours