HYW-1095 T6

Power Solutions / DC RANGE

HYW-1095 T6

Open Skid

Prime power1,280 kVA
Standby power1,364 kVA

TECHNICAL DATA

Specifications

Model code
G-1710-11-1-3
Engine
YANMAR
Alternator
STAMFORD
Fuel
Diesel
Frequency
60 Hz
Phase
Three phase
Emissions
non certified
Version
Open Skid
Prime power
1,024 kW
Standby power
1,091 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
416/240 V 60 Hz Three phase STAMFORD
480/277 V 60 Hz Three phase STAMFORD
440/254 V 60 Hz Three phase STAMFORD
460/265 V 60 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.800 r.p.m. Rated Engine Output: 1071,9kW prp ; 1144,9kW standby Manufacturer: YANMAR Model: AY40L.ET Engine Type: 4-stroke diesel Injection Type: Direct Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 12-V Bore and Stroke: 155 x 180 mm Displacement: 40,76 L Cooling System: Coolant Lube Oil Specifications: API CF or CH4, SAE 15W-40 Compression Ratio: 14,35;1 Fuel Consumption 100% PRP: 275 l/h Fuel Consumption 75 % PRP: 211,3 l/h Fuel Consumption 50 % PRP: 149,6 l/h Fuel Consumption 25 % PRP: 90,6 l/h Lube oil consumption with full load: 0,75 Total oil capacity including tubes, filters 190 L Governor Type Electrical Air Filter Type Dry Inner diameter exhaust pipe: 205 mm Oil temperature sensor Low coolant level sensor Exhaust gas compensator Diesel engine 4-stroke cycle Water-cooled 24V electrical system Standard air filter Standard fuel filter Standard oil filter Radiator with pusher fan Radiator water level sensor HTW sender LOP sender Hot parts protection Moving parts protection Water separator filter (visible level) (Optional)

Alternator

Generator: STAMFORD Model: HCI634K Poles: 4 Connection type (standard): Star-series Mounting type: S-00 21" Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Steel chassis Emergency stop button Oil sump extraction kit Anti-vibration shock absorbers Chassis with integrated fuel tank Fuel level gauge Manual oil drain pump High mechanical strength Fuel tank drain plug Fuel transfer pump (Optional) Steel industrial silencer -15db(A) attenuation (Optional) Steel residential silencer -35db(A) attenuation. (Optional)

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Connection panel wired to the safety protection (open thermal magnetic protection and alarm) Maintenance-free and anti-explosion battery Battery Switch Control panel and emergency stop button Battery charger (standard on gensets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Heating resistor (standard on sets with automatic control panels) (Optional) - EXHAUST SYSTEM. Maximum exhaust temperature: 455 ºC Exhaust Gas Flow: 256,3 m3/min Maximum allowed back pressure: 6 kPa - NECESSARY AMOUNT OF AIR. Intake air flow: 5862 m3/h Cooling Air Flow: 26,88 m3/s Alternator fan air flow: 1,961 m3/s - STARTING SYSTEM. Starting power: 8 kW Starting power: 10,88 CV Recommended battery: 75 x 4 Ah Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: Diesel Fuel Tank: 400 L

Dimensions

- DIMENSIONS. Length: 4.450 mm Height: 2.313 mm Width: 2.100 mm Maximum shipping volume: 21,61 m3 Fuel tank capacity: 400 L Autonomy: 2 Hours