HGS-1310 T6 NG

Power Solutions / HP RANGE

HGS-1310 T6 NG

Open Skid

COP power1,304 kVA

TECHNICAL DATA

Specifications

Model code
G-1896-11-1-3
Engine
GUASCOR
Alternator
STAMFORD
Fuel
Natural Gas
Frequency
60 Hz
Phase
Three phase
Emissions
non certified
Version
Open Skid

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
416/240 V 60 Hz Three phase STAMFORD
480/277 V 60 Hz Three phase STAMFORD
440/254 V 60 Hz Three phase STAMFORD
460/265 V 60 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.800 r.p.m. Rated Engine Output: 1350kW cop Manufacturer: GUASCOR Model: G.56HM Engine Type: 4-stroke Otto Cycle Injection Type: Carburization Aspiration Type: Turbocharged Number of cylinders and arrangement: 16-V Bore and Stroke: 160 x 175 mm Displacement: 56,3 L Cooling System: Water Lube Oil Specifications: SAE 40 Compression Ratio: 11,9 Fuel Consumption 100% PRP: 3211 kW Fuel Consumption 80 % PRP: 2624 kW Fuel Consumption 75 % PRP: 2443 kW Fuel Consumption 50 % PRP: 1737 kW Fuel Consumption 25 % PRP: 1032 kW Lube oil consumption with full load: 0,15 Total oil capacity: 419 L Governor Type Electrical Air Filter Type Dry Natural Gas engine 4-stroke cycle Water-cooled Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: S7L1D.C4 Poles: 4 Connection type (standard): Star Mounting type: S-00 18" Insulation: H class Enclosure (according IEC-34-5): IP23 Voltage regulator: A.V.R. (Electronic) Bracket type: Double drive-shaft Coupling system: Elastic Coupling Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Emergency stop button Steel chassis Steel industrial silencer -15db(A) attenuation Steel residential silencer -35db(A) attenuation. - GAS RAMP. Manual shut-off valve Double solenoid valve High pressure regulator Primary pressure regulator Secondary pressure regulator (Zero pressure regulator) Low pressure switch High pressure switch Valve (tightness) testing system Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Battery Switch Adjustable earth leakage protection (time & sensitivity) standard in M12, with thermal magnetic protection Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) - EXHAUST SYSTEM. Maximum exhaust temperature: 420 ºC Exhaust Gas Flow: 1,86 kg/s Maximum allowed back pressure: 450 mm H2o - NECESSARY AMOUNT OF AIR. Cooling Air Flow: 26,75 m3/s Alternator fan air flow: 3,25 m3/s - STARTING SYSTEM. Auxiliary Voltage: 12 Vdc - FUEL SYSTEM Fuel Oil Specifications: Natural Gas