HGS-1030 T6 LPG

Power Solutions / HP RANGE

HGS-1030 T6 LPG

Soundproof

COP power1,033 kVA

TECHNICAL DATA

Specifications

Model code
G-1857-11-1-4
Engine
GUASCOR
Alternator
STAMFORD
Fuel
LPG
Frequency
60 Hz
Phase
Three phase
Emissions
non certified
Version
Soundproof

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
416/240 V 60 Hz Three phase STAMFORD
480/277 V 60 Hz Three phase STAMFORD
208/120 V 60 Hz Three phase STAMFORD
220/127 V 60 Hz Three phase STAMFORD
440/254 V 60 Hz Three phase STAMFORD
460/265 V 60 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.800 r.p.m. Rated Engine Output: 1067kW cop Manufacturer: GUASCOR Model: G.56SM Engine Type: 4-stroke Otto Cycle Injection Type: Carburization Aspiration Type: Turbocharged Number of cylinders and arrangement: 16-V Bore and Stroke: 160 x 175 mm Displacement: 56,3 L Cooling System: Water Lube Oil Specifications: SAE 40 Compression Ratio: 9,2 Fuel Consumption 100% PRP: 2774 kW Fuel Consumption 80 % PRP: 2300 kW Fuel Consumption 75 % PRP: 2163 kW Fuel Consumption 50 % PRP: 1550 kW Fuel Consumption 25 % PRP: 965 kW Lube oil consumption with full load: 0,1 Total oil capacity: 272 L Governor Type Electrical Air Filter Type Semi-humid LPG-liquefied petrol gas engine 4-stroke cycle Water-cooled Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: S6L1D.G4 Poles: 4 Connection type (standard): Star Mounting type: S-00 18" Insulation: H class Enclosure (according IEC-34-5): IP23 Voltage regulator: A.V.R. (Electronic) Bracket type: Double drive-shaft Coupling system: Elastic Coupling Coating type: Standard (Vacuum impregnation)

Version

- CONTAINER VERSION. Soundproofing provided by high-density volcanic rock wool High mechanical resistance Low level of noise emissions Door with window to visualize control panel, alarms and measurements Reinforced lifting points for crane hoisting and lower ones for transportation by forklift Residential steel silencer with -35dB attenuation and tilting cap in the exhaust Anti-vibration shock absorbers Steel chassis Manual oil extraction pump Robust construction designed for continuous or emergency applications Stainless steel fittings Emergency stops Easy access to the power connection Reinforced chassis for heavy range Easy access for chassis cleaning Silent-block with anti-corrosion protection between the genset and the chassis Easy access to fill radiator through the roof - GAS RAMP. Manual shut-off valve Gas filter Double solenoid valve High pressure regulator Primary pressure regulator Low pressure switch High pressure switch Valve (tightness) testing system Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence

Installation

- ELECTRICAL SYSTEM CONTAINER. Control panel and emergency stop button Power panel Battery charger (standard on automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charge alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Battery isolator - EXHAUST SYSTEM. Maximum exhaust temperature: 512 ºC Exhaust Gas Flow: 1,43 kg/s Maximum allowed back pressure: 450 mm H2o - NECESSARY AMOUNT OF AIR. Alternator fan air flow: 2,34 m3/s - STARTING SYSTEM. Auxiliary Voltage: 12 Vdc - FUEL SYSTEM Fuel Oil Specifications: LPG

Dimensions

- DIMENSIONS. Length: 12.192 mm Height: 2.896 mm Width: 2.438 mm Maximum shipping volume: 86,08 m3