HGP-1000 T5 NG

Power Solutions / HP RANGE

HGP-1000 T5 NG

Soundproof

Prime power1,002 kVA
Standby power1,116 kVA

TECHNICAL DATA

Specifications

Model code
G-1796-10-2-4
Engine
PSI
Alternator
STAMFORD
Fuel
Natural Gas
Frequency
50 Hz
Phase
Three phase
Emissions
non certified
Version
Soundproof
Prime power
802 kW
Standby power
893 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase STAMFORD
415/240 V 50 Hz Three phase STAMFORD
200/115 V 50 Hz Three phase STAMFORD
380/220 V 50 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 842kW prp ; 941kW standby Manufacturer: PSI Model: 53L Engine Type: 4-stroke Otto Cycle Injection Type: Direct Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 16-V Bore and Stroke: 150 x 185 mm Displacement: 52,3 L Cooling System: Coolant Lube Oil Specifications: SAE 15W40; API CD or CE Compression Ratio: 10,5:1 Fuel Consumption ESP: 2688 kW Fuel Consumption 100% PRP: 2442 kW Fuel Consumption 75 % PRP: 1900 kW Fuel Consumption 50 % PRP: 1374 kW Fuel Consumption 25 % PRP: 866 kW Total oil capacity: 171 L Total coolant capacity: 248 L Governor Type Electrical Air Filter Type Dry Natural Gas engine 4-stroke cycle Water-cooled 12V electrical system Dry air filter Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: S6L1D.E4 Poles: 4 Connection type (standard): Star-series Mounting type: S-0 18'' Insulation: H class Enclosure (according IEC-34-5): IP23 Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- CONTAINER VERSION. Soundproofing provided by high-density volcanic rock wool High mechanical resistance Low level of noise emissions Door with window to visualize control panel, alarms and measurements Reinforced lifting points for crane hoisting and lower ones for transportation by forklift Residential steel silencer with -35dB attenuation and tilting cap in the exhaust Anti-vibration shock absorbers Steel chassis Manual oil extraction pump Robust construction designed for continuous or emergency applications Stainless steel fittings Emergency stops Easy access to the power connection Reinforced chassis for heavy range Easy access for chassis cleaning - GAS RAMP. Manual shut-off valve Gas filter Double solenoid valve Primary pressure regulator Secondary pressure regulator (Zero pressure regulator) Low pressure switch High pressure switch Inlet pressure manometer Outlet pressure manometer Special Start/Stop sequence High pressure regulator (Optional)

Installation

- ELECTRICAL SYSTEM CONTAINER. Control panel and emergency stop button Power panel Battery charger (standard on automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charge alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Battery isolator - EXHAUST SYSTEM. Maximum exhaust temperature: 625 ºC Exhaust Gas Flow: 150 m3/min Maximum allowed back pressure: 13 kPa - NECESSARY AMOUNT OF AIR. Alternator fan air flow: 1,41 m3/s - STARTING SYSTEM. Starting power: 10 x 2 kW Starting power: 13,6 x 2 CV Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: Natural Gas

Dimensions

- DIMENSIONS. Length: 12.192 mm Height: 2.896 mm Width: 2.438 mm Maximum shipping volume: 86,08 m3