HGM-1520 T5 NG

Power Solutions / HP RANGE

HGM-1520 T5 NG

Open Skid

COP power1,521 kVA

TECHNICAL DATA

Specifications

Model code
G-1145-10-1-3
Engine
MTU
Alternator
LEROY SOMER
Fuel
Natural Gas
Frequency
50 Hz
Phase
Three phase
Emissions
Cumple EPA
Version
Open Skid

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase LEROY SOMER

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 1560kW cop Manufacturer: MTU Model: 12V4000L64.FNER Engine Type: 4-stroke Otto Cycle Injection Type: Carburization Aspiration Type: Turbocharged Number of cylinders and arrangement: 12-V Bore and Stroke: 170 x 210 mm Displacement: 57,2 L Cooling System: Water + Antifreeze Lube Oil Specifications: SAE 40 Compression Ratio: 12,5 Fuel Consumption 100% PRP: 3428 kW Fuel Consumption 75 % PRP: 2619 kW Fuel Consumption 50 % PRP: 1823 kW Total oil capacity: 280 L Governor Type Electrical Air Filter Type Dry Natural Gas engine 4-stroke cycle Water-cooled 24V electrical system Dry air filter Remote radiator HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: LEROY SOMER Model: LSA 52.3 L9 Poles: 4 Connection type (standard): Star Mounting type: S-00 21" Insulation: F class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Steel chassis Emergency stop button Anti-vibration shock absorbers Steel industrial silencer -15db(A) attenuation Steel residential silencer -35db(A) attenuation. (Optional) - GAS RAMP. Gas filter Double solenoid valve Gas pressure regulator Low pressure switch High pressure switch Inlet pressure manometer Outlet pressure manometer

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Battery Switch Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) - EXHAUST SYSTEM. Maximum exhaust temperature: 417 ºC Exhaust Gas Flow: 89,23 m3/min Maximum allowed back pressure: 60 mbar - NECESSARY AMOUNT OF AIR. Intake air flow: 5702 m3/h Alternator fan air flow: 2,5 m3/s - STARTING SYSTEM. Starting power: 9 kW Starting power: 12,24 CV Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: Natural Gas

Dimensions

- DIMENSIONS. Length: 8.777 mm Height: 2.692 mm Width: 2.150 mm Maximum shipping volume: 50,8 m3 Weight with liquids in radiator and sump: 15.960 kg