HGM-1135 T5 BIO

Power Solutions / HP RANGE

HGM-1135 T5 BIO

Soundproof

COP power1,134 kVA

TECHNICAL DATA

Specifications

Model code
G-1146-10-1-4
Engine
MTU
Alternator
STAMFORD
Fuel
Biogas
Frequency
50 Hz
Phase
Three phase
Emissions
non certified
Version
Soundproof

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 1200kW cop Manufacturer: MTU Model: 12V4000L32 Engine Type: 4-stroke Otto Cycle Injection Type: Carburization Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 12-V Bore and Stroke: 170 x 210 mm Displacement: 57,2 L Cooling System: Coolant Lube Oil Specifications: SAE 40 Compression Ratio: 13,9 Fuel Consumption 100% PRP: 19.455.81 cfh Fuel Consumption 75 % PRP: 14.950.25 cfh Fuel Consumption 50 % PRP: 10.698.93 cfh Lube oil consumption with full load: 0,2 Total oil capacity including tubes, filters 260 L Governor Type Electrical Air Filter Type Dry Biogas Engine 4-stroke cycle Water-cooled 24V electrical system Dry air filter Remote radiator HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: PI734E Poles: 4 Connection type (standard): Star Mounting type: S-00 21" Insulation: H class Enclosure (according IEC-34-5): IP23 Exciter system: Self-excited, brushless Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- CONTAINER VERSION. Soundproofing provided by high-density volcanic rock wool High mechanical resistance Low level of noise emissions Door with window to visualize control panel, alarms and measurements Reinforced lifting points for crane hoisting and lower ones for transportation by forklift Residential steel silencer with -35dB attenuation and tilting cap in the exhaust Anti-vibration shock absorbers Steel chassis Manual oil extraction pump Robust construction designed for continuous or emergency applications Stainless steel fittings Emergency stops Easy access to the power connection Easy access for chassis cleaning Silent-block with anti-corrosion protection between the genset and the chassis Easy access to fill radiator through the roof - GAS RAMP. Gas filter Double solenoid valve Gas pressure regulator Low pressure switch High pressure switch Inlet pressure manometer Outlet pressure manometer

Installation

- ELECTRICAL SYSTEM CONTAINER. Control panel and emergency stop button Power panel Battery charger (standard on automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charge alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) Battery isolator - EXHAUST SYSTEM. Maximum exhaust temperature: 445 ºC Exhaust Gas Flow: 79,3 m3/min Maximum allowed back pressure: 60 mbar - NECESSARY AMOUNT OF AIR. Intake air flow: 4415 m3/h Cooling Air Flow: 34,44 m3/s Alternator fan air flow: 2,69 m3/s - STARTING SYSTEM. Starting power: 9 kW Starting power: 12,24 CV Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: Biogas

Dimensions

- DIMENSIONS. Length: 12.192 mm Height: 2.896 mm Width: 2.438 mm Maximum shipping volume: 86,08 m3 Weight with liquids in radiator and sump: 28.725 kg Sound pressure level: 76 ± 2,4 dB(A)@7m