HBW-1385 T5

Power Solutions / HP RANGE

HBW-1385 T5

Open Skid

Prime power1,385 kVA
Standby power1,525 kVA

TECHNICAL DATA

Specifications

Model code
G-2169-10-3-3
Engine
BAUDOUIN
Alternator
STAMFORD
Fuel
Diesel
Frequency
50 Hz
Phase
Three phase
Emissions
non certified
Version
Open Skid
Prime power
1,108 kW
Standby power
1,220 kW

CONFIGURATION

Available voltages

VoltageFrequencyPhaseAlternatorDatasheet
400/230 V 50 Hz Three phase STAMFORD

INCLUDED

Equipment

Engine

Engine Specifications 1.500 r.p.m. Rated Engine Output: 1200kW prp ; 1320kW standby Manufacturer: BAUDOUIN Model: 12M33G1500.5 Engine Type: 4-stroke diesel Injection Type: Direct Aspiration Type: Turbocharged and after-cooled Number of cylinders and arrangement: 12-V Bore and Stroke: 150 x 185 mm Displacement: 39,2 L Cooling System: Liquid (water + 50% glycol) Lube Oil Specifications: API CI-4 or ACEA E7 Compression Ratio: 15:1 Fuel Consumption ESP: 330,5 l/h Lube oil consumption with full load: 0,3 % of fuel consumption Total oil capacity including tubes, filters 160 L Total coolant capacity: 188 L Governor Type Electrical Air Filter Type Dry Inner diameter exhaust pipe: 200 mm Oil temperature sensor Low coolant level sensor Exhaust gas compensator Diesel engine 4-stroke cycle Water-cooled 24V electrical system Standard air filter Standard fuel filter Standard oil filter Radiator with pusher fan HTW sender LOP sender Hot parts protection Moving parts protection

Alternator

Generator: STAMFORD Model: S7L1D.C4 Poles: 4 Connection type (standard): Star Mounting type: S-00 18" Insulation: H class Enclosure (according IEC-34-5): IP23 Voltage regulator: A.V.R. (Electronic) Bracket type: Single bearing Coupling system: Flexible disc Coating type: Standard (Vacuum impregnation)

Version

- OPEN SET VERSION. Steel chassis Emergency stop button Oil sump extraction kit Anti-vibration shock absorbers Chassis with integrated fuel tank Fuel level gauge Fuel tank drain plug Fuel transfer pump (Optional) Steel industrial silencer -15db(A) attenuation (Optional) Steel residential silencer -35db(A) attenuation. (Optional)

Installation

- ELECTRICAL SYSTEM. Electric control and power panel with measurements devices and control unit (according to necessity and configuration) Connection panel wired to the safety protection (open thermal magnetic protection and alarm) Maintenance-free and anti-explosion battery Battery Switch Battery charger (standard on gensets with automatic control panels) Heating resistor (standard on sets with automatic control panels) Battery charger alternator with ground connection Starter battery/ies installed (cables and bracket included) Ground connection electrical installation with connection ready for ground spike (not supplied) - EXHAUST SYSTEM. Maximum exhaust temperature: 550 ºC Exhaust Gas Flow: 277 m3/min Maximum allowed back pressure: 75 mbar - NECESSARY AMOUNT OF AIR. Intake air flow: 5838 m3/h Cooling Air Flow: 19 m3/s Alternator fan air flow: 2,71 m3/s - STARTING SYSTEM. Starting power: 10 kW Starting power: 13,6 CV Recommended battery: 75 x 2 Ah Auxiliary Voltage: 24 Vdc - FUEL SYSTEM Fuel Oil Specifications: Diesel

Dimensions

- DIMENSIONS. Length: 4.810 mm Width: 2.200 mm Weight with liquids in radiator and sump: 0 kg